***Coding for standard types is detailed below but for custom types, please consult the factory directly.
PANEL TYPE
C | = | Current Control |
M | = | Current Monitoring |
S | = | Current Splitter |
POLARITY TYPE
A | = | Anode |
B | = | Both Anode & Structure |
N | = | Not Applicable |
S | = | Structure |
ENCLOSURE TYPE (**see Note 1 below**)
3 | = | Standard Vented (3R) |
4 | = | Painted Steel (4 / 4X) |
F | = | Fiberglass (4X) |
H | = | Hazardous Location (consult factory) |
N | = | Not Required |
S | = | Stainless Steel (4 / 4X) |
X | = | Special (Please specify in other comments) |
CIRCUIT QUANTITY
# | = | Number of Circuits |
MAIN TERMINAL SIZE (**see Note 2 below**)
A | = | #4 – 14 AWG Lug Terminal |
B | = | 1/0 – #6 AWG Lug Terminal |
C | = | 4/0 – #2 AWG Lug Terminal |
N | = | Not Applicable |
X | = | Special (Please specify in other comments) |
CIRCUIT TERMINAL SIZE
A | = | #4 – 14 AWG Lug Terminal |
B | = | 1/0 – #6 AWG Lug Terminal |
C | = | 4/0 – #2 AWG Lug Terminal |
N | = | Not Applicable |
P | = | 5-Way Binding Post |
X | = | Special (Please specify in other comments) |
SHUNT TYPE (**see Note 3 below**)
J | = | Holloway Type “JB” |
N | = | Not Applicable |
R | = | Holloway Type “RS” |
S | = | Holloway Type “SS” |
Wa | = | Holloway Type “SW” (5A-50mV) |
Wb | = | Holloway Type “SW” (10A-50mV) |
Wc | = | Holloway Type “SW” (15A-50mV) |
Wd | = | Holloway Type “SW” (20A-50mV) |
We | = | Holloway Type “SW” (25A-50mV) |
Wf | = | Holloway Type “SW” (30A-50mV) |
Wg | = | Holloway Type “SW” (40A-50mV) |
Wh | = | Holloway Type “SW” (50A-50mV) |
Wx | = | Holloway Type “SW” (Please specify in other comments) |
X | = | Special (Please specify in other comments) |
MONITORING (**see Note 3 below**)
A | = | Ammeter (individual circuits only) |
B | = | Both Ammeter and Voltmeter |
C | = | Combination Meter (Volts/Amps Scale) |
H | = | Hour Meter |
N | = | No Meter Required |
P | = | Potential Meter |
T | = | Ammeter (individual circuits plus Total) |
ADJUSTMENT TYPE (**see Notes 3 & 4 below**)
E | = | Resistor (slide wire type) |
H | = | Rheostat |
N | = | Not Applicable |
ADJUSTMENT VALUE (**see Notes 3 & 4 below**)
N | = | Not Applicable |
Resistance | – | Wattage |
0.5 Ohms | – | 150 Watts Rheostat |
1.0 Ohms | – | 150 Watts Rheostat |
2.0 Ohms | – | 150 Watts Rheostat |
5.0 Ohms | – | 150 Watts Rheostat |
0.375 Ohms | – | 150 Watts Resistor |
1.0 Ohms | – | 150 Watts Resistor |
2.0 Ohms | – | 150 Watts Resistor |
OPTIONAL FEATURES
Various options available (i.e. specific labels, conduit entries, etc.). Please consult factory.
SAMPLE JUNCTION BOX / PANEL CODE
C A 3 – 05 – B2 A Wa N H – 0.5-150 – Z
NOTES
Note 1: | Current control (Type “C”) panel types are only available in the Type “3” enclosure. |
Note 2: | If more than one main input terminal is required, indicate it in Column 5, as shown (i.e. B2, B3, etc.). |
Note 3: | For “Current Splitter” type panels, the Shunt Type, Monitoring, Adjustment Type and Adjustment Value codes are not applicable and should be marked as an “N”. |
Note 4: | For “Current Monitoring” type panels, the Adjustment Type and Adjustment Value codes are not applicable and should be marked as an “N”. |