***Coding for standard types is detailed below but for custom types, please consult the factory directly.
PANEL TYPE
| C | = | Current Control |
| M | = | Current Monitoring |
| S | = | Current Splitter |
POLARITY TYPE
| A | = | Anode |
| B | = | Both Anode & Structure |
| N | = | Not Applicable |
| S | = | Structure |
ENCLOSURE TYPE (**see Note 1 below**)
| 3 | = | Standard Vented (3R) |
| 4 | = | Painted Steel (4 / 4X) |
| F | = | Fiberglass (4X) |
| H | = | Hazardous Location (consult factory) |
| N | = | Not Required |
| S | = | Stainless Steel (4 / 4X) |
| X | = | Special (Please specify in other comments) |
CIRCUIT QUANTITY
| # | = | Number of Circuits |
MAIN TERMINAL SIZE (**see Note 2 below**)
| A | = | #4 – 14 AWG Lug Terminal |
| B | = | 1/0 – #6 AWG Lug Terminal |
| C | = | 4/0 – #2 AWG Lug Terminal |
| N | = | Not Applicable |
| X | = | Special (Please specify in other comments) |
CIRCUIT TERMINAL SIZE
| A | = | #4 – 14 AWG Lug Terminal |
| B | = | 1/0 – #6 AWG Lug Terminal |
| C | = | 4/0 – #2 AWG Lug Terminal |
| N | = | Not Applicable |
| P | = | 5-Way Binding Post |
| X | = | Special (Please specify in other comments) |
SHUNT TYPE (**see Note 3 below**)
| J | = | Holloway Type “JB” |
| N | = | Not Applicable |
| R | = | Holloway Type “RS” |
| S | = | Holloway Type “SS” |
| Wa | = | Holloway Type “SW” (5A-50mV) |
| Wb | = | Holloway Type “SW” (10A-50mV) |
| Wc | = | Holloway Type “SW” (15A-50mV) |
| Wd | = | Holloway Type “SW” (20A-50mV) |
| We | = | Holloway Type “SW” (25A-50mV) |
| Wf | = | Holloway Type “SW” (30A-50mV) |
| Wg | = | Holloway Type “SW” (40A-50mV) |
| Wh | = | Holloway Type “SW” (50A-50mV) |
| Wx | = | Holloway Type “SW” (Please specify in other comments) |
| X | = | Special (Please specify in other comments) |
MONITORING (**see Note 3 below**)
| A | = | Ammeter (individual circuits only) |
| B | = | Both Ammeter and Voltmeter |
| C | = | Combination Meter (Volts/Amps Scale) |
| H | = | Hour Meter |
| N | = | No Meter Required |
| P | = | Potential Meter |
| T | = | Ammeter (individual circuits plus Total) |
ADJUSTMENT TYPE (**see Notes 3 & 4 below**)
| E | = | Resistor (slide wire type) |
| H | = | Rheostat |
| N | = | Not Applicable |
ADJUSTMENT VALUE (**see Notes 3 & 4 below**)
| N | = | Not Applicable |
| Resistance | – | Wattage |
| 0.5 Ohms | – | 150 Watts Rheostat |
| 1.0 Ohms | – | 150 Watts Rheostat |
| 2.0 Ohms | – | 150 Watts Rheostat |
| 5.0 Ohms | – | 150 Watts Rheostat |
| 0.375 Ohms | – | 150 Watts Resistor |
| 1.0 Ohms | – | 150 Watts Resistor |
| 2.0 Ohms | – | 150 Watts Resistor |
OPTIONAL FEATURES
Various options available (i.e. specific labels, conduit entries, etc.). Please consult factory.
SAMPLE JUNCTION BOX / PANEL CODE
C A 3 – 05 – B2 A Wa N H – 0.5-150 – Z
NOTES
| Note 1: | Current control (Type “C”) panel types are only available in the Type “3” enclosure. |
| Note 2: | If more than one main input terminal is required, indicate it in Column 5, as shown (i.e. B2, B3, etc.). |
| Note 3: | For “Current Splitter” type panels, the Shunt Type, Monitoring, Adjustment Type and Adjustment Value codes are not applicable and should be marked as an “N”. |
| Note 4: | For “Current Monitoring” type panels, the Adjustment Type and Adjustment Value codes are not applicable and should be marked as an “N”. |